Key Features of the Acoustic Leak Locator

ALL™ Components:

  • Airborne, structure-borne, and combined applications are possible
  • Modular design – 2 to 16 channels per enclosure
  • Dual Signal Processing Modules
  • Microprocessor Control in each module
  • Programmable gain of 60dB in 2dB steps
  • Bandwidth from 1KHz to 500KHz, unfiltered
  • Jumper-selectable airborne/structure-borne filter range
  • Continuous root-mean-square (RMS) signal processing on each channel
  • Programmable HI and LO alarm thresholds and delays for each channel
  • Solid-state alarm output relays (optional)
  • 4-20 mA or 0-5 VDC analog outputs for each channel.  For use on plant DCS
  • All microprocessor boards are durable yet designed for easy replacement in minutes
  • Local keypad or remote Personal Computer (PC) control of parameter settings
  • Key-lock protection of parameter settings
  • Parameter settings are retained after power loss
  • RS-232 or RS-422 serial I/O communication option
  • TCP/IP converter optional
  • All modules are bus-connected for ease of troubleshooting
  • Rackmount or benchtop enclosure option

AMI Technical Services

  • One-day installation training
  • Unlimited telephone technical assistance
  • Available setup / maintenance / operation training, and installation inspection
  • Warrantied for 18 months from date of shipment or 13 months from date of installation
  • Exchange Repair Service–we troubleshoot down to what component needs repaired, and ship an exchange component overnight to you.

Find out more by reading technical papers and case studies on leak detection

Click the images below for larger versions